More than $50 free shipping      One Year Quality Guarantee      30-day money-back guarantee

Email: service.alandental@gmail.com
SINNOR SNP9000L-D 8'' Patient Monitor 6 Parameters (ECG NIBP RESP TEMP SPO2 PR)
  • SINNOR SNP9000L-D 8'' Patient Monitor 6 Parameters (ECG NIBP RESP TEMP SPO2 PR)

  • Item No. ADL004114
  • Brand:SINNOR

  • But It Now : $449.98
    Voltage :
    Plug :
    Quantity :

  • Limit points for buying:400 score
  • Weight:0gram
  • Goods click count:8
Item Description Reviews

SINNOR SNP9000L-D 8'' Patient Monitor 6 Parameters (ECG NIBP RESP TEMP SPO2 PR)

SINNOR SNP9000L-D 8'' Patient Monitor 6 Parameters (ECG NIBP RESP TEMP SPO2 PR)

Features:

1. With accessory management cabinet.

2. 8 inch high resolution color TFT display.

3. USB interfaces support easy software upgrade and data transfer.

4. Three Working Modes: Monitoring, Surgery and Diagnosis.

5. Simple and friendly operating display interface.

6. Multi-display modes suitable for different applications:     Standard Interface, Large font, ECG Standard Full Display, OXY , Trend Table, BP Trend.

7. Built-in battery up to 3 hours of continuous work.

 

Standard Parameters:

ECG, RESP, TEMP, NIBP, SPO2, PR

 

Technique Specification:

ECG

1. Lead Mode: 5 Leads (I, II, III, AVR, AVL,AVF, V)

2. Gain: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV

3. Heart Rate: 15-300 BPM (Adult); 15-350 BPM (Neonatal)

① Resolution: 1 BPM

② Accuracy: ±1%

③ Sensitivity >200 uV(Peak to peak)

4. ST measurement range: -2.0 ~ +2.0 mV

① Accuracy: -0.8mV~+0.8mV: ±0.02mV or ±10%, which is greater

Other Range: unspecified

5. Sweep speed: 12.5 mm/s, 25mm/s, 50mm/s

6. Bandwidth:

7. Diagnostic: 0.05~130 Hz

8. Monitor: 0.5~40 Hz

9. Surgery: 1~20 Hz

 

SPO2

1. Measuring Range: 0 ~ 100 %

2. Resolution: 1%

3. Accuracy: 70% ~ 100% (±2 %)

4. Pulse Rate: 20-250 BPM

5. Resolution: 1 BPM

6. Accuracy: 3 BPM

 

NIBP

1. Method: Oscillometry

2. Measure mode: Manual, Auto, STAT

3. Unit: mmHg, kPa

4. Measure and alarm range:

5. 1 Adult Mode

① SYS 40 ~ 280 mmHg

② DIA 10 ~ 225 mmHg

③ MEAN 20 ~ 240 mmHg

5. 2 Pediatric Mode

① SYS 40 ~ 220 mmHg

② DIA 10 ~ 160 mmHg

③ MEAN 20 ~ 170 mmHg

5. 3 Neonatal Mode

① SYS 40 ~ 135 mmHg

② DIA 10 ~ 100 mmHg

③ MEAN 20 ~ 110 mmHg

6. Resolution: 1mmHg

7. Accuracy: 5mmHg

 

RESP

1. Method: Impedance between RA-LL or RALA

2. Measurement Range:

① Adult: 10 ~ 120 BrPM

② Neonatal / Pediatric: 7 ~ 150 BrPM

3. Resolution: 1 BrPM

4. Accuracy: 2 BrPM

 

TEMP

1. Measure and Alarm Range: 0 ~ 50℃

2. Resolution: 0.1℃

3. Accuracy: 0.1℃

 

Standard Configuration:

Main Unit *1

5-lead ECG cable *1

Disposable ECG Electrode *5

Adult Spo2 probe *1

Adult NIBP cuff *1

NIBP extension tube *1

Temperature probe *1

Power Cable *1

User Manual *1

 

SINNOR SNP9000L-D 8'' Patient Monitor 6 Parameters (ECG NIBP RESP TEMP SPO2 PR)

SINNOR SNP9000L-D 8'' Patient Monitor 6 Parameters (ECG NIBP RESP TEMP SPO2 PR)

SINNOR SNP9000L-D 8'' Patient Monitor 6 Parameters (ECG NIBP RESP TEMP SPO2 PR)

SINNOR SNP9000L-D 8'' Patient Monitor 6 Parameters (ECG NIBP RESP TEMP SPO2 PR)

SINNOR SNP9000L-D 8'' Patient Monitor 6 Parameters (ECG NIBP RESP TEMP SPO2 PR)

 

SINNOR SNP9000L-D 8'' Patient Monitor 6 Parameters (ECG NIBP RESP TEMP SPO2 PR)

SINNOR SNP9000L-D 8'' Patient Monitor 6 Parameters (ECG NIBP RESP TEMP SPO2 PR)

 

SINNOR SNP9000L-D 8'' Patient Monitor 6 Parameters (ECG NIBP RESP TEMP SPO2 PR)

SINNOR SNP9000L-D 8'' Patient Monitor 6 Parameters (ECG NIBP RESP TEMP SPO2 PR)


Contact Information:
Email: service.alandental@gmail.com
If you have any problem, please do not hesitate to contact us.

Shipment Note:
If your package shipped by Express Delivery, please give us a valid delivery phone number, and also a full and accurate shipping address.


How to Buy from Alandental?


Prev: 35L/50L/75L/100L Vertical Dental Pressure Steam Autoclave Sterilizer
Next: SINNOR SNP9000L-B 8'' Patient Monitor 4 Parameters (NIBP SPO2 PR TEMP)
Buy more related dental equipment and Save more!
Latest Dental News
Latest Dental News
View History[clear]