DAVID BM-100 Series Portable Neonatal Transcutaneous Bilirubin Jaundice Tester Handheld Jaundice Meter
  • DAVID BM-100 Series Portable Neonatal Transcutaneous Bilirubin Jaundice Tester Handheld Jaundice Meter

  • Item No. ADL003937
  • Brand:DAVID
  • Manuals and Documentation:

    • EOFY sales 2026:
    • 6% Off On Total Order Amount!
    • Enjoy Discount at Checkout! No Need Coupon Code!
    • Valid Till June 30th,2026

  • But It Now : $1449.98
    Voltage :
    Plug :
    Model :
    Quantity :

  • Weight:0gram
  • Goods click count:321
Item Description Reviews

DAVID BM-100 Series Portable Neonatal Transcutaneous Bilirubin Jaundice Tester Handheld Jaundice Meter

 

 
Introducing the BM-100 series jaundice meter from NB David, available in 2 models - BM-100A and BM-100C.
 
Function and Model Selection
 
BM-100A BM-100C
- 3" colour touch screen
- long battery life (2000 measurements per full charge)
- storage of patient information and results
- long life span(> 150,000 scans)
- self calibration
- As included in BM-100A plus;
- bar code/ QR reader to scan Baby ID/ Nurse ID
- USB transfer of data
 
BM-100A: Use for community settings or when the need for scanning and USB transfer is not needed
BM-100C: Offering extra features, the BM-100C is suitable when you want to scan patient ID and transfer data via USB.
 
Features
Multiple scenes: applied to neonatology, paediatrics, delivery room, neonatal ward and NICU, etc;
Colorful display screen: 3.0 inch color touch screen, on-screen display of multiple measurement data, ensure the excellent operation experience;
Chargeable battery: Equipped with charging base, enduring built-in chargeable battery, measuring 2000 times after battery is full;
Enduring light source: xenon flash lamp with long lifespan (measurement:>150,000 times),
Low voltage indication: an low voltage indication will be activated by low battery capacity,
Unit conversion: converting between two kinds of measurement unit mg/dL, µmol/L;
Measurement mode: this function permits 2~5 times setting of average measurement;
Data storage and transmission: multiple patients'data can be stored
Charging base with the function of integrated light checker, consumable-free, saving cost for check.
Constant measurement to multiple patients without repeating calibration; Average measurement: this function permits 1~5 times setting of average measurement to ensure the accuracy on results;
 
Technical Specification
Screen Type: 3" LCD Colour Touchscreen
Light Source: Xenon flash lamp
Light Source Lifetime: Not less than 150,000 measurements
Data Storage: Internal memory of 100 records
Data Transmission: USB data transfer (BM-100C)
Units of Measurement:mg/dl or µmol/L
Measurement Range:0.0 - 25.0 mg/dl or 0 - 425µmol/L
Measurement Accuracy: ±1.5 mg/dl  or ±25.5µmol/L
Battery: Lithium
Charging Time: 2000
Number of Measurements from Full Charge Unit lifetime: 6 years
Quality Standards:1S013485, 93/42/EEC and CE Certificate
 
Operating Environment Requirements
Temperature: 5°C - 40°C
Humidity: ≤90%RH
Atmospheric Pressure: 500hPa -1060hPa
 
Transport Environment Requirements
Temperature: -20°C - 55°C
Humidity: ≤90%RH
Atmospheric Pressure: 500hPa -1060hPa
 
Unit Dimensions (WxDxH):60 x 46 x 175mm
Base Dimensions (WxDxH):85 x 155 x 106mm
Unit Weight:252g
Base Weight:237g
 
DAVID BM-100 Series Portable Neonatal Transcutaneous Bilirubin Jaundice Tester Handheld Jaundice Meter
 
DAVID BM-100 Series Portable Neonatal Transcutaneous Bilirubin Jaundice Tester Handheld Jaundice Meter
 
DAVID BM-100 Series Portable Neonatal Transcutaneous Bilirubin Jaundice Tester Handheld Jaundice Meter
 
DAVID BM-100 Series Portable Neonatal Transcutaneous Bilirubin Jaundice Tester Handheld Jaundice Meter
 
DAVID BM-100 Series Portable Neonatal Transcutaneous Bilirubin Jaundice Tester Handheld Jaundice Meter
 
DAVID BM-100 Series Portable Neonatal Transcutaneous Bilirubin Jaundice Tester Handheld Jaundice Meter
 
DAVID BM-100 Series Portable Neonatal Transcutaneous Bilirubin Jaundice Tester Handheld Jaundice Meter
 
DAVID BM-100 Series Portable Neonatal Transcutaneous Bilirubin Jaundice Tester Handheld Jaundice Meter
 
DAVID BM-100 Series Portable Neonatal Transcutaneous Bilirubin Jaundice Tester Handheld Jaundice Meter
 
DAVID BM-100 Series Portable Neonatal Transcutaneous Bilirubin Jaundice Tester Handheld Jaundice Meter
 
DAVID BM-100 Series Portable Neonatal Transcutaneous Bilirubin Jaundice Tester Handheld Jaundice Meter
 
DAVID BM-100 Series Portable Neonatal Transcutaneous Bilirubin Jaundice Tester Handheld Jaundice Meter
 
DAVID BM-100 Series Portable Neonatal Transcutaneous Bilirubin Jaundice Tester Handheld Jaundice Meter
 
DAVID BM-100 Series Portable Neonatal Transcutaneous Bilirubin Jaundice Tester Handheld Jaundice Meter

Contact Information:
Live Support: Chat with us online
Email: service.alandental@gmail.com
If you have any problem, please do not hesitate to contact us.

Shipment Note:
If your package shipped by Express Delivery, please give us a valid delivery phone number, and also a full and accurate shipping address.


How to Buy from Alandental?


Prev: Luckcome L6H Fetal Doppler at Home, Hand Held Fetal Doppler Ultrasound, Baby Heart Monitor for Pregnancy
Next: DAVID XHZ-90/90L Neonatal Phototherapy Lamp Bilirubin Lights Phototherapy Light For Jaundice
Buy more related dental equipment and Save more!
Latest Dental News
Latest Dental News