> Getidy JCH 16L/18L/23L Dental Autoclave Sterilizer Class N With Drying Function
Item DescriptionReviews
Getidy JCH 16L/18L/23L Dental Autoclave Sterilizer Class N With Drying Function
Features:
Class N, white light imported digital LED screen for pressure and temperature, Motorola pressure sensor, Double control with electric and mechanical lock, automatic temperature control and Over-heat protection, automatic drying function (with heating ring), equipped with two large diameter imported electromagnetic valves, automatic drainage and steam exhaust
Heating to pressure 0.70bar(HE.1)→the first exhaust(TE.1)→Heating to pressure 1.70bar (HE.2)→the second exhaust(TE.2)→Heating to pressure 2.20bar (HE.3)→ Start 135℃ Sterilization(Lasts 6 minutes)→the third exhaust(TE.3)→Balance to pressure0.00bar (LED display
“END”) → open the door (Sterilization completed).
“121℃ Program” button:
Heating to pressure 0.70 bar(HE.1)→the first exhaust(TE.1)→Heating to pressure 1.00bar (HE.2) →the second exhaust(TE.2)→Heating to pressure 1.20bar (HE.3)→ Start 122℃ Sterilization(Lasts 25 minutes)→the third exhaust(TE.3)→Balance to pressure0.00bar(LED display “END”)→open the door (Sterilization completed).
“Dry” Program button:
Caution: Dry program working needs the door is open. Press “Dry” program button, the indicator starts to flash. Then press “START/STOP” button to start 19-minute dry program during indicator flashing
“Exhaust” button :
When sterilizer was not running, but found high pressure inside. That’s need to use “Exhaust” button. Operation: 1.Click “Exhaust” button. 2.Indicator will turn from “OFF” to “ON”. 3. Indicator turned back to “ON”. 4. Door can be opened. 5.5 “Abnormally Exit”
“Abnormally Exit”:
Operation can be used during program running, but you want to stop.
Operation: 1. Hold on pressing “START/STOP” button 3 seconds, 2.Temperature window showing flashing “E00”. And sterilizer started exhaust. 3.Click “START/STOP” again after pressure window showing 0.0 bar with the sound KA from lock opened. 4.Door can be opened until temperature window showing
Warning:
Operators must read and understand the following six points before using this sterilizer!
1.The sterilizer is a professional equipment. Operator must be trained and master professional knowledge before operating it!
2.Before starting the sterilization, please ensure that water inside is sufficient! To avoid burning the instruments, due to lack of water!
3.Be sure to close the door in place. Push the door handle to the bottom so that door handle surface is flush with the door panel.
4. The tightness of the door sealing must be checked each 30 days. When the door is closed in place, the force required for door handle is 15Kgs, which is considered to be the right tightness of the door. Otherwise the door sealing is too loose will cause steam leakage. In severe cases, the door gasket will be exploded, accompanied with a loud steam explosion sound. Therefore, the operator should stay away during sterilizer working from start to the end of cycle.
5.Door,gasket and chamber surface should be cleaned and maintained after each cycle!
6.lf the door handle was loose when closing, the door handle screws must be tightened before staring sterilization.