Tag Archives: clean

HOW TO MAINTAIN DENTAL AIR COMPRESSORS Correctly

An air compressor is capable of working under all types of weather, providing that the compressor is kept in optimal shape and the operating environment is suited to the technology. With periodic maintenance of your compressed air system and its room of operation, you could enjoy optimal performance throughout the year with minimal downtime. Therefore, it’s wise to mark each of the following steps onto select seasonal dates of your working calendar.

The temperature that surrounds a dental air compressor is integral to the quality of the machine’s performance. If the air that surrounds the compressor is hotter than normal due to rising outdoor temperatures, it can affect the performance of pneumatic tools and machines. Therefore, it’s crucial to ensure that the air compressor itself maintains consistent temperatures throughout the year, including those months where outdoor temperatures top 80 degrees.

In order to prevent an air compressor from getting hotter during summer, the coolers must be cleaned each year just as temperatures begin to rise. If the coolers are clogged, it could impede their ability to keep your compressed air system at desired levels. To prevent this from happening, perform the following actions several weeks in advance of each summer: Inspect the coolers for traces of dirt, gunk or misty residue. Clean away any dirt deposits present on the coolers.

If the air compressor gets overheated, the impact could be troublesome for the compressor itself, as well as for any attached pneumatic tools and machinery. If a compressor is used to power air blowers, for example, the quality of air that reaches the end point could be ill–suited to the task at hand when the system is overheated.

The filtration system is integral to the efficiency of an air compressor. As long as the air and oil are sufficiently filtered throughout a given cycle, the air compressor can be expected to produce cool air at consistent volumes with an overall smooth performance from the machine. However, if the filters are clogged with dirt, pressure drop can ensue, and this forces the air compressor to work harder just to perform basic functions. Consequently, energy gets consumed and parts get worn in the process.

Maintenance of an air compressor unit is only part of what keeps a compressed air system in optimal condition throughout the four seasons of a given year. In order to keep a well–functioning compressor performing up to par, you also need to ensure that the compressor room is maintained with optimal working conditions for the machinery contained within.

The Importance of Dental Sterilizer

Today’s busy dental practices face a serious challenge: to maintain or increase productivity while ensuring that patient safety remains a top priority. At times, these may seem like incompatible goals. Advances in dental processing equipment, however, have empowered practices to develop safer processes while realizing efficiencies and ultimately, saving money.

Sterilizers are medical devices, requiring clearance by the Food and Drug Administration before manufacturers may offer them for sale. The FDA requires rigorous testing to ensure an adequate margin of safety in each cycle type described in the instructions. Failing to follow the instructions of the manufacturer is ill advised, since it may result in inadequate sterilization of the instruments or devices in the sterilizer. It is never appropriate to use a household device, such as a toaster oven, for sterilization of dental equipment.

A cleaning and sterilization process that meets ADA and CDC guidelines is vital to an effective infection control program. Streamlining of this process requires an understanding of proper methods, materials, and devices. Many methods of instrument reprocessing are available. Use of a complete system that encompasses and fulfills all elements that are critical maximizes efficiency and minimizes risks. Closed cassette systems provide a more efficient and safer way to process, sterilize and organize instruments in a dental office – these eliminate manual steps during instrument reprocessing such as hand scrubbing and time-consuming sorting of instruments, thereby improving safety and increasing efficiency.

Dry heat sterilizers have been used effectively in dental office for many years. Just as with any other sterilization method, dry heat sterilization is highly dependent upon the operator following the manufacturer’s instructions for cycle time, temperature, instrument packaging, and loading technique. Because dry air is not as efficient a heat conductor as moist heat at the same temperature, a much higher temperature is required for a dry heat unit to accomplish sterilization.

Packaging cleaned instruments prior to placing them in the autoclave sterilizer is a standard of care that protects instruments and maintains their sterility until they are ready for use on a patient. Unprotected instruments may be re-contaminated with dust and spatter or by coming into contact with any number of non-sterile surfaces during transport, storage, tray set-up, and operatory set-up.

The Use of Dental Suction Units

There are two main types of dental suction unit that dentists use: the saliva ejector and the high volume suction. The saliva ejector does exactly what its name implies; it sucks saliva out of the mouth. This is the suction pictured at the upper right of this article. Many times dentists will have the patient close down on this suction so that it can suction away any remaining saliva in the patient’s mouth.

The other main type of dental suction that we use is the high volume suction. This suction is so strong that the dental assistant simply holds it close to where the dentist is working and it will suck away any nearby debris, much like a strong vacuum cleaner can suck away crumbs without actually touching them.
Why Dentists Use a Dental Suction

Now that the introductions are over, let’s talk about some of the different reasons why dentists will use a suction.
For Patient Comfort

Keeping the patient comfortable is a high priority. We suction after giving anesthetic because the anesthetic has a bitter taste, and most patients prefer to rinse out with water and use the saliva ejector. Also, if the anesthetic sits in the back of your mouth for too long, it may start to slightly numb the back of your mouth and could give the patient a gagging sensation.

We will also use the suction to make sure that you don’t get too much water in your mouth while we are working.
To Clean Away Any Excess Dental Materials

When a dental hygienist cleans and polishes your teeth, you can get a lot of cleaning paste in your mouth. We use the suction to help clean all of that away. Also, when dentists are do amalgam fillings, pieces of the soft amalgam can sometimes fall away from the tooth surface. We use the suction to help whisk them away.
To Keep the Tooth Dry

During some procedures, such as white fillings, it is important that the tooth stay clean and dry. The suction helps keep the tooth dry by sucking away any saliva, blood, and water that may have accumulated around the tooth. If the cavity went below the gum-line, then it’s pretty likely that the gums will bleed during the filling.

The Sterilization Information about Dental Autoclave Sterilizer

Today’s busy dental practices face a serious challenge: to maintain or increase productivity while ensuring that patient safety remains a top priority. At times, these may seem like incompatible goals. Advances in dental processing equipment, however, have empowered practices to develop safer processes while realizing efficiencies and ultimately, saving money.

A cleaning and sterilization process that meets ADA and CDC guidelines is vital to an effective infection control program. Streamlining of this process requires an understanding of proper methods, materials, and devices. Many methods of instrument reprocessing are available. Use of a complete system that encompasses and fulfills all elements that are critical maximizes efficiency and minimizes risks. Closed cassette systems provide a more efficient and safer way to process, sterilize and organize instruments in a dental office – these eliminate manual steps during instrument reprocessing such as hand scrubbing and time-consuming sorting of instruments, thereby improving safety and increasing efficiency.

Care must be taken by the dental healthcare professional to ensure that all instruments are cleaned prior to sterilization, and that this is carried out in a safe manner to avoid injury and puncture wounds. Use of closed-system cassettes reduces the risk to dental healthcare professionals when executing infection control programs. When using ultrasonic cleaners, washers and sterilizers, it is important to always follow the manufacturer’s instructions.

It is also important to consult with the manufacturer of dental instruments and devices as needed to ensure complete sterilization and to avoid damage to these items. Assurance of sterility of instruments and devices can be obtained through the use of one of several tests, and these tests must be performed regularly to ensure that the sterilizer is sterilizing all instruments and devices and that these are safe for use on patients.

Parameters such as time, pressure and temperature vary according to the type of autoclave sterilizer, materials being sterilized and individual models within sterilizer brands. The first step in determining the settings for the sterilizer is to refer to the manufacturer’s instructions. Sterilizers are medical devices, requiring clearance by the Food and Drug Administration before manufacturers may offer them for sale. The FDA requires rigorous testing to ensure an adequate margin of safety in each cycle type described in the instructions. Failing to follow the instructions of the manufacturer is ill advised, since it may result in inadequate sterilization of the instruments or devices in the sterilizer. It is never appropriate to use a household device, such as a toaster oven, for sterilization of dental equipment.